9V Alkaline Battery Operated Ionization Detector, With Silencer
Original price was: KSh 4,400.00.KSh 4,060.00Current price is: KSh 4,060.00.
- Power Source: Battery
- 11.0cm Diameter
- Color: White
- Type: Smoke Detector
- 5 Years Warranty
-
Operating Sound: 85db
- Description
- Reviews (0)
Description
9V Alkaline Battery Operated Ionization Detector, With Silencer
The 9V Alkaline Battery Ionization Smoke Detector with Silencer is a general-purpose protective device for residential, commercial, and industrial use for smoke presence alarm in case of smoke in the atmosphere and is powered with a 9V alkaline battery. It is equipped with a silencer (hush) feature, through which one can temporarily mute the alarm in case of spurious alarm trips.
The following is a complete detail about its most significant features, operations, and application:
1. Ionization technology:
Ionization Smoke Detector: Ionization smoke detectors utilize a small source of radioactivity between two plates that have an electrical charge placed between them. The radioactivity ionizes the surrounding air, creating a current of ions (charged particles).
When smoke particles move through the chamber, they perturb the ionized environment, and a current drop happens. Consequently, an alarm is generated, and smoke, and even a fire, is detected.
Ionization detectors react most sensitively to quick-flaming fires, producing minute, invisible smoke particles that will not necessarily become observable initially but can produce quick, strong fires.
2. 9V Alkaline Battery Power:
Power Source: It is powered with a 9V alkaline battery, a convenient and easy battery to swap out, and one that can be purchased in most stores and supermarkets.
Battery Life: It will have a life of about 1-2 years, depending on use and demand for stand-by power for the detector.
Low Battery Indicator: There will be an alarm, a sequence of short chirps in most cases, when a low battery must be replaced, in an attempt to preserve the device in a working state for ongoing protection.
3. Silencer (Hush) Feature:
The silencer feature is a useful one that can muffle spurious alarm activations, such as those produced by smoke during cooking, steam, or even dust. It proves to be particularly useful in areas such as kitchens and toilets, where ambient factors can make an alarm sound even when no real fire is detected.
How it works: In case of a false alarm, one can press “hush” or “silence” button of alarm and temporarily mute it for a short period, say 5 to 10 minutes
This feature is convenient for the user, in that it enables them to respond to the cause of the smoke (e.g., cooking, steam) without having to re-reset the alarm, or even shut it down altogether.
4. Audible Signal:
The alarm sound is sharp and loud, typically 85 decibels and louder, and is loud enough to awaken one even in a crowded room or sleeping state.
The alarm will predominantly produce a loud, continuous sound, or a series of intermittent beeps, and will have a purpose of commanding one’s attention and eliciting immediate reaction in case of smoke presence.
5. Test button:
The test button enables one to verify that the smoke detector works. By pressing the button, one simulates smoke and sets off the alarm, and one can confirm that the device works appropriately.
Routine Testing: It is advisable to have the alarm checked monthly, or according to manufacturer recommendations, to verify that it continues to function and that its battery is in working condition.
6. LED Indicator:
The LED alarm light will, under normal circumstances, report the smoke alarm’s current state:
Green/Blue LED: Indicates that the detector is in a healthy state and nothing is ailing with it.
Flashing Red LED: In most cases, it will indicate smoke detected and in alarm state.
Flashing Yellow/Amber LED: Indicates a low battery level, such as a device failure, for example
7. Compact and Simple Installation:
The 9V Ionization Smoke Detector is fairly small and light, and can, for that reason, be mounted in a variety of locations, such as walls and ceilings.
Installation usually involves screwing in the unit with screws, and it can be performed both by a homeowner and a professional installation expert.
Some models feature adhesive mounting for simple installation with reduced use of drills.
8. Maintenance and Replenishment of Battery:
Battery Replacement: The 9V alkaline battery will have to be replaced at least one times a year, or whenever a low-battery alarm occurs, but with a new, high-quality alkaline battery for correct function.
Cleaning: Regular cleaning is important in maintaining the sensitivity of the detector in a working state. Debris and dust can generate interference with device performance, and vacuuming or wiping with a soft cloth gently to remove any debris is therefore advisable.
9. Applications:
Residential: These types of alarm can be mounted in residential environments, most specifically in corridors, bedrooms, kitchens, and basements. Ionization types, in specific, can detect fires with quick flaming and less conspicuous smoke.
Commercial Use: It can be installed in small retail shops, retail stores, and any commercial buildings in which a wired system cannot and is not a necessity for installation.
Mobile and Transitory Installments: Due to its battery-powered build, such a detector can simply be installed in caravans, RVs, and transitory structures, and can, therefore, best function in mobile applications.
10. Compliance and Standards:
The 9V Alkaline Ionization Smoke Detector typically complies with important fire safety standards such as UL 217 (Underwriters Laboratories) in the United States or EN 14604 in Europe. These standards ensure that the device meets reliability, durability, and performance requirements.
The device will have to be installed according to local codes for fires, and in most instances, smoke detectors will have to be installed in specific locations in a building for optimal protection against fires.
11. Design and Appearance:
The device will have a discreet, simple shape with a white cover, and it will not draw any undue attention, blending in with most environments effortlessly.
The front of the unit will most frequently feature a small LED indicator and a test button for ease of use.
The 9V Alkaline Battery Operated Ionization Silencer Smoke Detector is a cost-effective and dependable smoke alarm for residential and small commercial applications. Ionization technology identifies rapid flaming fires with efficiency, and a silencer feature aids in mutes unnecessary alarm through an easy switch, no device disconnection is involved. With ease of installation, long battery life, and national compliance, this smoke alarm is an imperative in any alarm system for fires, offering peace of mind and protecting lives and property in case of fires.
Reviews
There are no reviews yet.