Manual Override Gas Release System

Manual Override Gas Release System

Manual Override Gas Release System

Original price was: KSh 7,300.00.Current price is: KSh 7,145.60.

In stock

Original price was: KSh 7,300.00.Current price is: KSh 7,145.60.

Power/Voltage
24 V DC
Body Material
ABS
Usage
Gas Release
Current Rating
25 Amp
Pack Type
Box
SKU: C9317 Category:

Description

Manual Override Gas Release System

The Manual Override Gas Release C9317 is a specifically designed protective device for use in fire suppression systems, in areas in which discharge of suppression chemicals (like CO2 or FM-200) is desired but in areas in which a necessity for security, for controlling, could arise through a manual intervention. C9317 is a device designed to enable an override function for a manual discharge of a gas-suppressed suppression chemical into a safeguarded zone, superseding programmed system controls.

Here’s a complete rundown of Manual Override Gas Release System C9317’s key features, function, and application:

1. Primary function:
The C9317 Manual Override Gas Release System enables a fire suppression system to be initiated through a manual override, in this case, for use with gas-based suppression agents. Manual override systems are most often utilized in settings that demand a rapid and efficient mechanism for extinguishing fires with no use of water, including museums, electrical rooms, data centers, and archives.
The manual override feature is important in an emergency when an automatic system will not work under certain conditions, or when one person must insure suppression agent is delivered at a critical point in time.

2. Manual Activation:
The system provides direct access for discharge controlling of the fire suppression agent. In most instances, it is a lever or button that, when actuated by personnel, discharges the agent into the zone to smother out, at least, the fire.
The manual override is designed to override automat, and operators can utilize it in cases of failure, in cases of human errors, or in any other specific cases in which automat will not function best.

3. Safety Features:
The C9317 system is constructed with numerous security options in case of an unintended discharge. For one, it can have a lockout mechanism or pins that have to first be taken out or disengaged in order for discharge to occur in a manual manner.
The system is designed in such a manner that discharge can only be initiated when an absolute necessity, and no unnecessary downtime, and even not damaging delicate equipment with early discharge of suppression agent can occur.
Visual and sound warnings can be included in the system to inform that the discharge mechanism is in use, providing loud and conspicuous warnings to nearby persons.

4. Integration with Fire Suppression Systems:
The C9317 system can be paired with a range of gas suppression systems, such as CO2, FM-200, and NOVEC 1230 systems. It can be programmed through the fire alarm and control panel for actuating discharge of suppression agent.
It typically involves a controlling console in a distance, or a controlling post, located at a secure distance from the guarded area, through which operators can switch on the system in a secure manner, out of any danger.

5. Manual Overriding and Automated Interaction:
While the C9317 can function in a manual, its most common use is in conjunction with an automatic fire alarm system. In an automatic system, smoke, thermal, and flame detectors can be included that will trip discharge of the suppression agent when predetermined values have been attained.
The manual override creates a secondary level of control for when the automatic system fails to detect a timely fire and for when a trained operator will have to override and discharge the agent in a manual manner, providing for quick intervention.

6. Activation Lever/Button:
The activation button or lever is actually the device operators utilize in order to deliberately cause discharge of the gas. It is a large, accessible button or pull lever that involves a conscious act in an attempt to prevent accidental firing.
Some systems have a key that one must turn, and/or enter a password, in order for a manual initiation to become operational, and permit only authorized persons to discharge the suppression agent.

7. Control Panel
The C9317 system will most frequently include a board that interfaces with a fire suppression system. That board can report system state, inform a user of any faults, and report the state of the state of current state of the fire suppression system.
The panel can include lights for indications of override mechanism state, such as whether it is in an armed and ready state for use, and whether an agent is released.
Remote monitoring can even become a consideration, with off-site monitoring of the system, or even in a single room of controls.

8. Alarm System:
When the system is started manually, C9317 will sound both audible and visual warnings to notify persons in immediate surrounding of discharge of suppression agent.
These alarms inform individuals that suppression is in operation and, when required, that they have to evacuate the room. The alarms serve to denote when discharge of the gas begins, and operators can view the incident in real-time.

9. Applications:
Data Centers and Server Rooms: Where sensitive computers like servers or electronic networks face attack in terms of fires, suppression with gases such as CO2 or FM-200 can protect valuable gear. Manual intervention can be with the C9317 when a delayed discharge in an automatic alarm could not permit timely discharge.
Telecommunications Rooms: Similar to data centres, telecommunication rooms have sensitive gear that will have to be protected in case of fires. There is a feature of a manual override, allowing suppression agents to be delivered effectively and intentionally when needed.
Museums and Archives: Archives and museums have significant and irreplacable contents that can suffer water damage. For them, a gas suppression system is most effective, and C9317 is a device that can make them work when in use.
Industrial and Toxic Environments: Factories, chemical processing, and any other types of industrial environments in which flammable chemicals are stored and/or utilized can even have a manual override feature incorporated in its fire suppression system.

10. Maintenance and Testing:
The C9317 system will require its maintenance and testing periodically in a manner that will enable it to work effectively. It entails checking whether its override mechanism is working effectively, whether its mechanism for releases is in a working state, and whether any faults in its control panel and its wiring are present.
Regular system inspections must involve alarm testing, a determination that the override mechanism’s battery or source of power is operational, and a determination that the control board is providing correct system information.
The system will have to be examined for any corrosion, wear, and tear, especially when installed in an industrial environment or hostile environment.

11. Compliance and Requirements for Safety:
The C9317 Manual Override Gas Release System is designed in compliance with proper international and local standards for fire protection, such as NFPA (National Fire Protection Association) standards for suppression systems and ISO (International Organization for Standardization) standards.
Compliance with such standards will ensure that the system is delivering effective and reliable protection, and its override function in compliance with high performance and safety requirements.

The Manual Override Gas Release System C9317 is an important part of fire suppression systems, offering a level of manual override over suppression agent releases during times of emergency. With its override feature, it enables operators to override automatic controls and activate suppression agent when and when not when desired, providing increased adaptability and dependability in protecting against fires. It is particularly useful in areas with sensitive machinery, important assets, and dangerous chemicals, in which quick, measured intervention can mean all the difference in protecting assets and lives and in lessening loss and damage.